Exports

CAD drawing export

The layered drawing export — every layer and what it carries, why coordinates are in metres, and which layers are conditional on your settings.

The CAD drawing export writes the plant as a layered drawing: the boundary, the exclusions, the tables, the equipment, the cables, the trenches and your annotations, each on a layer of its own. It is the deliverable for a drafting or engineering team — the people who will take the layout apart, dimension it, add their own details and issue construction drawings from it.

It is not a picture of the layout. The report's drawing page is that. This file is geometry a drafter can work in, at true size, with everything separable.

Who it is for, and what they get

RecipientWhat the layers give them
A drafting teamSeparable geometry to dimension, annotate and issue
A civil engineerThe boundary, the excluded ground and the contours, without the electrical clutter
An electrical engineerCable routes and trench routes, by type, without the structures
A survey or setting-out teamReal coordinates that can be checked against a survey

Anyone who only needs to look at the layout is better served by the Google Earth export or the report — neither needs CAD software.

Coordinates are real, in metres

Every coordinate in the drawing is in metres, in the site's own projected coordinate zone — the local UTM zone. The application works in that zone internally and converts only at the edges, so nothing is scaled, fitted or normalised on the way out.

Three consequences, all of them the point:

  • The drawing is at true size. A distance measured in CAD is the distance on the ground, in metres. No drawing scale factor has to be applied or remembered.
  • It can be referenced against a survey. Open the drawing alongside survey data in the same UTM zone and the two overlay directly, with no fitting step.
  • It can be set out from. A coordinate read off the drawing is a coordinate a setting-out crew can use.

Check the zone before combining the drawing with anything else. Survey data supplied in a different projection, in feet, or in a local site grid will not overlay, and the mismatch is easy to miss because both drawings look plausible on their own.

The layers

Grouped below by what they belong to. The layer names are exactly as they appear in the drawing's layer list.

Site

LayerCarriesColour
BOUNDARYThe plant boundariesYellow
PERIMETER_ROADThe road setback band, as two outline polylines with no fillGrey
OBSTACLESExclusion zones from the boundary fileRed
WATERWater bodiesLight blue
OBSTRUCTIONSObstructions you drew yourselfGreen
TERRAINReduced-level contour linesGrey

The kept-clear ground arrives as separate layers rather than as one. OBSTACLES and WATER are treated differently on site — a building or a substation is an obstacle to be worked around, a pond is a water body with its own consequences — and OBSTRUCTIONS holds what you drew by hand rather than what the boundary file declared, so a recipient can tell the two apart. See Obstructions.

PERIMETER_ROAD is the band between the plant boundary and the usable area, and it comes across as two outline polylines with no fill — the outer edge and the inner edge. A drafter therefore receives the road reserve as boundaries to work with rather than as a solid to delete, and the same band is the one drawn on the plot and in the report. See How placement works.

Array

LayerCarriesColour
TABLESEvery placed module table or tracker unitBlue

One layer for the whole array. Switch it off and the site, the equipment and the cabling are all still there — which is how a drafter works on anything other than the modules.

Tables are written as block references, not as individual outlines. Every table of a given size is an insert of one shared block definition, so editing that block in your CAD program updates every table in the plant at once. The block's own geometry sits on layer 0, so each insert takes the properties of the layer it is placed on, which is standard CAD practice. Tell the drafting team: a change to the table detail is one edit, not tens of thousands.

Equipment

LayerCarriesColour
ICRThe inverter control roomsCyan
MCRThe main control roomViolet
INVERTERS, or SMB in Central Inverter modeThe string inverters, or the string monitoring boxesLime
OBJECTSThe objects you placedBrown
STREET_LIGHTThe street-light polesOrange
LAThe lightning arrester symbolsMaroon — written only when arresters were placed

The equipment layer name follows the electrical mode. In a Central Inverter design the layer is named SMB and carries the string monitoring boxes, because the central inverters themselves sit inside the control room rather than out among the tables. See Inverter control rooms.

Keep-clear shadows

LayerCarriesColour
ICR_MCR_SHADOWThe year-round keep-clear shadow of the control roomsGrey
OBJECT_SHADOWThe keep-clear shadow of the placed objectsGrey
STREET_LIGHT_SHADOWThe keep-clear shadow of the street lightsGrey

Three layers a recipient will otherwise mistake for stray hatching. Each one is the ground a structure shadows across the shadow window — and with Clear tables inside shadows on, which is its shipped state, that is the ground the tables were cleared from. The shadow layers are therefore the justification for the gap in the array beside every building, object and pole. Keeping them separate means a drafter can show that justification or switch it off, and a civil engineer can see which cleared ground is shadow rather than obstruction. See Structures and shadow.

Cables

LayerCarriesColour
DC_CABLESDC string cablesOrange
AC_CABLESAC cables from the invertersMagenta
MV_CABLESMedium-voltage cables, control room to main control roomGreen

Three layers rather than one, because the three are different cables with different sizes, different burial requirements and usually different contractors. All three are written only when cable calculation was on for the run — see the conditional layers below.

Trenches

LayerCarriesColour
DC_TRENCHDC trench routesGreen
AC_TRENCHAC trench routesRed
MV_TRENCHMedium-voltage trench routesDark green

A trench and a cable are not the same length, and that is why they are on separate layers. Several cables share one trench, so trench routes are the de-duplicated routes on the ground while the cable layers carry the conductor runs. The trench layers are what a civil contractor prices and excavates. See Cable routing.

Drafting

LayerCarriesColour
SKETCHAll Sketch Mode annotationsWhite
ANNOTATIONSLabels and textWhite
Screenshot pendingexports/dxf-cad.png
An exported drawing file in a CAD program
What it shows
A CAD program with the exported drawing open and the layer panel visible, so the layer names can be read against the drawing.
How to get there
Export the drawing file and open it in AutoCAD or BricsCAD, and show the layer manager. The frame is the CAD program, not the save window.
Callouts to add
Outline the layer list.

Three layers that may be absent

Most of the layers above are written on every export, whether or not they have anything in them. Three are conditional, and a layer that is not in the file is usually a setting you chose rather than a fault in the export.

Conditional layerWritten whenColour
DC_CABLES, AC_CABLES, MV_CABLESCable calculation was on for the runOrange, magenta, green
LALightning arresters were placedMaroon
PILESA pile pattern has been definedOrange

The first two settings are off by default and no pile pattern exists until you define one. So a first export, produced from a first run at the defaults, has no cable layers, no arrester layer and no pile layer — and that is correct behaviour rather than a missing export. Piles are defined in the pile layout editor; see Piles.

If the recipient needs cable and trench routing, tick Calculate Cables for PV Power Plant and generate again before exporting. Cable calculation is the slow step on a large plant, which is why it is off to begin with — the recommended order is to review the layout first, then enable it for the final run.

Your annotations come across

Everything you drew in Sketch Mode — the lines, polylines, rectangles, circles, arcs, splines, fills and dimensions — is written to the SKETCH layer, and the labels and text land on ANNOTATIONS.

Keeping them on their own layers is deliberate, and it is worth telling the recipient: your working notes, sketched intent and markup are separable from the plant. They can switch the layers off and have the plant with none of your commentary on it, or leave them on and read what you were pointing out. Neither requires them to delete anything.

The layers you create in Sketch Mode do not become CAD layers. The exported layer set is fixed to the ones listed above, so every annotation lands on the single SKETCH layer whichever in-application layer it was drawn on. If the recipient has to be able to separate one set of markup from another, distinguish them by colour or by a text label, or issue them as separate exports — the layer structure will not carry the distinction across.

See Annotations for the drawing tools themselves.

Before you export

Turn cable calculation on, if routing is needed

Generate again with Calculate Cables for PV Power Plant ticked. Without it there are no cable layers, the trench layers hold nothing but what you drew by hand, and a trenching estimate cannot be made from the drawing.

Finish the layout edits

Hand-placed tables, deleted tables, drawn obstructions, moved control rooms and hand-drawn trenches all export, so make them before you write the file rather than after. See Sketch Mode.

Clear the annotations you do not want issued

Anything left in Sketch Mode goes into the file on the SKETCH layer. It is separable, but it is still in the drawing. 🗑 Clear Annotations removes it.

Export the drawing

Click Export DXF in the export block beside the plot. Choose the folder and the file name; the file type is fixed to .dxf.

The Save DXF window, with an empty file name field and the file type set to DXF files.
Saving the drawing file

Open it and check the layer list

Open the file and read its layer list against the tables above. This one check catches the common surprises immediately — no cable layers because the run had cables off, no arrester layer because arresters were off, no pile layer because no pattern was defined. All three are fixed before the export, not by exporting again.

Limits

  • It is geometry, not a drawing set. There is no border, no title block, no drawing number and no revision block. Those are the recipient's, in their own template.
  • Nothing is dimensioned unless you dimensioned it. The dimensions in the file are the ones you drew in Sketch Mode.
  • It carries no quantities. Take those from the bill of materials rather than counting entities in CAD.
  • The single-line diagram is exported separately. It is not part of this file. See Exporting the diagram.