Inputs
Generation degradation
The Year-1 and Year-2-onward loss applied to Solar and Wind generation over the project life.
The ๐ Degrad. tab sets how much Solar and Wind generation itself declines over the project life โ separate from the battery's own state-of-health degradation on the ๐ BESS tab.

Fields
| Field | Default | Range | What it does |
|---|---|---|---|
| Generation Loss Year-1 | 1.0% | 0โ5% | Solar/Wind generation loss in Year 1 |
| Generation Loss Year-2+ | 0.4%/yr | 0โ2%/yr | Annual generation loss from Year 2 onward |
The tab's own caption describes the two figures as compounding โ each year's generation factor is (1 minus the Year-1 loss) multiplied by (1 minus the Year-2+ loss) raised to the power of (year minus 1) โ and captions the shipped defaults as "1% Year-1, 0.4%/yr thereafter (IEC 61215 standard module degradation)".